mounted cold camera

The assembled cold camera, ready to go!

Somewhere back in the mists of time, an astrophotographer (E.S. King - 1912, Hoag - 1960) noticed that certain types of film seemed to perform better during winter months than they did during the summer months. In simple terms, it took longer to expose to a set density level when the ambient temperature was warm than when it was cold. Not only did cold film hold it's speed better, the colours were more accurate. This simple observation spawned a new tool for astrophotgraphy - the cold camera.

Closer studies showed that film tended to peak in performance in the -30 to -40C temperature range, which ruled out simply using ice to chill the film. Dry ice (frozen CO2 gas) weighs in at about -79C which is a bit too cold for film, but due to heat losses in most cameras the film usually sits somewhere near -40. One minor problem with cooling film this low is that it attracts moisture like a magnet! Within seconds frost forms on the film and inside the camera. Regular camera bodies would soon rust if adapted for dry-ice photography, or become unreliable when running so cold. So, a simplified camera body was needed, as was a way to keep air from hitting the film.

Early model cold cameras used one of two methods to keep the frost problem under control. The camera was a simple box, with an optical window at one end and film pinned against a cooling plate on the other. If the camera body was packed with dessicant, in theory there wouldn't be any moisture left to condense on the film. Another alternative was to pull a vacuum on the camera, again removing moisture from inside the camera body. This approach was best suited to the permanent observatory. A common problem with both of these approaches was that the film could droop away from the cooling plate, creating 'warm' spots on the film, and often dramatic changes to image density. Eventually someone hit upon the idea of pushing an optical plug in contact with the film, preventing airflow around the film and stopping condensation from forming. Early models (such as the Celestron/Williams model) used glass optical plugs. Glass has relatively good thermal conduction, which meant that within a matter of minutes condensation would form on the telescope side of the optical plug, which is exposed to the night air. For years, people used electrical heaters to warm the plug and keep it clear. Finally, someone used plexiglass for the optical plug which has much lower thermal transfer characteristics, and it now took an hour or more for the optical plug to fog over. With this, the modern cold camera was born.

A Comparison of Ambient vs. Chilled

Ambient at approx -5C Chilled to approx -40C
6" f4.5 with 120 format Ektachrome 400, 30 minutes 6" f4.5 with 120 format Ektachrome 400, 10 minutes


Back in 1986 I caught wind of a cold camera manufacturer in Victoria, Canada that went by the name of Canda Technologies, run by Leo Van der Byl. I was not happy with the way my astrophotos were turning out, so I took a gamble and bought a camera. It turned out to be a good investment - I have shot a few hundred photos with this camera over the fourteen years I have had it, it is still working flawlessly. Canda Technologies shut down in the late '80's, but Jack Newton's company Northern Lites popped up to take up the slack. Jack has since removed himself from the cold camera manufacturing scene, the only remaining source of these gems is at swap tables at star parties.

Cold Camera Parts


The above photo shows the major parts of the Canda Technologies camera. (Northern Lites models are similar) A Cut-away side view drawing of the camera is available here. The major pieces from left to right are:
Working with dry-ice

One question I often get is "how do you keep dry-ice?" Easy! First you must find some, local ice producers or ice-cream manufacturers usually have dry-ice lying around. I get mine from "Alberta Ice" here in Calgary, it costs just over $1.00 per pound. I recommend getting the compressed "nuggets" of dry-ice, they last much longer than dry-ice "snow". About the only way to store dry-ice for any length of time is in a glass Thermos - a big mouth version makes it easier to get the ice in and out. Each regular sized Thermos will hold 2 pounds of dry-ice. Use gloves when pouring the ice into the Thermos! Dry-ice burns are painful. Keep the lid of the Thermos loose. If not, sublimating dry ice will cause your new Thermos to explode! You don't need to keep the Thermos in a freezer, it is more important to keep it upright, so the cold stays in the Thermos. I initially fill 3 Thermos's, then use the third to keep the other two topped up. When down to 2, keep one topped up. You can make 6 pounds last to 10 days without any trouble - long enough for any star party.

Taking the shot

The following section may seem like a lot of work, but with practice you can go from closing the shutter, heating, finding the next object, focusing, cooling and opening the shutter down to 30 minutes. Not much longer than with a regular 35mm camera exposure.

To start with, you will need a polar aligned, equatorially mounted scope with your choice of aperature, focal ratio, etc. If you plan on using a filter, attach it to the shutter assembly now. Attach the shutter assembly to the focuser, or to the off-axis guider if you use one. Put your favourite 1.25" widefield eyepiece in to the eyepiece adapter, put the adapter in to the shutter assembly and open the shutter. Find your target, and set up your guidestar as usual. Next, swing your scope to the nearest naked-eye star for focusing. Remove the eyepiece holder, and insert the optical plug that you plan to use. Optical plugs can vary in thickness by several thousandths of an inch, it is very important that you focus with the plug you will be shooting with. Gently put the focusing tool over the optical plug, and focus the scope. Put the eyepiece back in, and re-acquire your target and guide star. Remove the eyepiece, insert the optical plug and close the shutter! (voice of experience here!)

The next step is to ensure that the top surface of the optical plug is clean. I use a soft camel hair brush and a can of compressed air to clean the surface. Don't shake the can when spraying, you can shoot liquid propellant on to the plug if you are not careful. Next I shake out some dry ice into the Thermos 'cup' and crush it up a bit. Fill the dry-ice chamber with crushed ice, and quickly screw down the spring loaded plunger assembly. Remove the bottom cap from the camera (in total darkness) and loosly put the camera over the shutter assembly. Advance the film a couple of frames and then tighten up the camera to the shutter. Over the next minute or so, creaks and groans come from the camera and ice as everything settles down to working temperatures. Tighten up the dry-ice plunger, reposition the guide star and when everthing is ready, open the shutter.

After your exposure, there will a white ball of frost sitting on your scope with a plunger sticking out of the top! If you were to try to advance the film now it would shatter, and water would condense on the pieces. Now, the camera must be warmed up. Start by removing the shutter assembly from the focuser, and remove any filter you may be using. Unscrew the plunger assembly, and tip any unused dry-ice back in to the Thermos. Grab the nearest hair dryer, (12v or 110v) and point it into the dry-ice chamber. After a few minutes, the frost will have melted from the camera body, and the frost on the cold plate will turn to water. At this time lift the camera body straight up from the shutter about 1/2 inch, and advance the exposed film into the film cannister. Lift the camera off the shutter, and replace the cap. If you have only one plug, heat it up so that the ends don't fog up. Put the shutter back on the scope, and you are ready to go again.

Believe it or not, this whole process is easier to do than it is to write down! It doesn't take long to develop your own style.

Care and feeding of optical plugs

I always carry four optical plugs with me, it speeds up the process by not having to heat the plugs up after heating up the camera. Eventually, no matter how careful you are with the focusing tool, the plugs will scratch. Small surface scratches don't cause much trouble, as they are in contact with the film and can't scatter light very far. Deeper scratches will cast shadows on the film. Jack Newton put me on to 'Novus Plastic Polish - #2' to remove fine scratches. You will need two soft cloths, one to polish the surface, the other to buff it. Jack also advised that toothpaste will also remove scratches, but I have never tried it.

Films that work

I haven't shot the cold camera since 1996, films have changed during this time. I will publish newer data if and when I get it. If anyone has any data, I would love to publish it here. I am just one guy, there is only so much testing I can do! Plus, as I now use CCD cameras, I don't have much urge to test new films.

Films that workedFilms that didn't work
Kodak Ektachrome SeriesFujicolour Print Film
Kodak Tri-XKodak Tech Pan
Fujichrome Slide FilmKodak PJM

Finally, a picture

This shot I took back in 1991, using a C8 at f10. This is a cropped shot of Hubble's Variable nebula taken on Ektachrome 400, chilled for 35 minutes, manually guided.

Hubbles Variable

Further Reading

Astrophotography - Equipment - Articles - CCD's - Home